THE ULTIMATE SMALL
DIAMETER VARIABLE FREQUENCY DRIVE CABLE CONNECTION SOLUTION
CHOOSE SERIES V ENHANCED DESIGN SMALL DIAMETER VARIABLE FREQUENCY DRIVE CABLES FOR:
- Interconnection
of Variable Frequency Drive Systems and Motors
For Extended Duty Cycle Performance Requirements
- Low Capacitance for Improved Signal Transmission
- Elimination of Downtime from Cable Failure
- Oil Resistance
- Improved Cable Life
- Longer Cable Runs
SERIES
V ENHANCED DESIGN SMALL DIAMETER VARIABLE FREQUENCY DRIVE CABLE APPLICATIONS:
- UL Exposed Run (-ER) Compliant to NEC Section 725.61 (D) (4) and NEC Section 336.10(7)
- Multi-Axis Control
Systems
- Automotive Assembly
Equipment
- Factory Equipment
Interconnects
- Robotics
- Machine Tools
- Stationary Track/Tray
- Conveyor Systems
- Control Panels
AVAILABILITY
- Stock, Bulk, Cut to Length
FIT®
TUBING RECOMMENDATION
FIT®-221
General Purpose, Irradiated Polyolefin
FIT®-321V Low Shrink Temp., Flame Retardant, Irradiated Polyolefin
|

CHARACTERISTICS
OPERATING
TEMPERATURE:
- 25°C
to 90°C (UL: Wet or Dry)
VOLTAGE
RATING:
- UL Listed Type
TC 600 Volt
- UL 1000 Volt Flexible
Motor Supply Cable
COLOR
DESCRIPTION:
- Color Code: Conductors 1, 2, and 3: Black Insulation with Alpha Numeric Printing
(Example: 1 - One)
Conductor 4: Green/Yellow for Ground (IEC Standard)
- Brake Pair Color Code: Black and White without Numeric Print
- Jacket Color:
Black
PRODUCT
DESCRIPTION:
- Conductor: Stranded
Tinned Copper
- Insulation: XLPE
(Cross-Linked Polyethylene)
- Drain Wire: Stranded
Tinned Copper
- Shield: Aluminum/Polyester/Aluminum, Drain Wires, Plus Overall Tinned Copper Braid 85%. Four Symmetrical Drain Wires on 8, 6, 4 and 2 AWG Cable
- Jacket: Specially-Formulated,
Oil Resistant PVC
SPECIFICATIONS
- UL Standard 1277, Type TC-ER, 90°C, 600 Volt
- CE-LVD: 73/68/EEC Amend. 93/68/EEC
- UL Exposed Run (-ER)
- UL Direct Burial
- UL Sunlight Resistant
- UL Type XHHW-2 RHW-2 (2-14 AWG Only)
- UL 1581 Vertical Tray
- UL 1000 Volt Flexible Motor Supply Cable
- CSA FT-4 Vertical Tray
- CSA AWM I/II A/B XHHW-2 RHW-2 Singles
|
SERIES V - VARIABLE FREQUENCY DRIVE CABLE WITHOUT BRAKE PAIR
Alpha
Part No. |
No.
of
Cond. |
|
Drain Wire Equiv. AWG Size [Physical Drains - AWG - (Strand)]
|
|
| Conductor To Conductor, pF/Ft |
Conductor To Shield, pF/Ft |
|
Continuous Current Per Conductor, Max. @30C (NEC)
|
|
|
| V16016 |
4 |
16 |
26/30 |
16 [1-16 (26/30)] |
0.535 |
13,6 |
21 |
38 |
12 |
4.3 |
34 |
| V16014 |
4 |
14 |
41/30 |
14 [1-14 (41/30)] |
0.575 |
14,6 |
23 |
42 |
25 |
4.6 |
37 |
| V16012 |
4 |
12 |
65/30 |
12 [1-12 (65/30)] |
0.627 |
15,9 |
26 |
47 |
30 |
5.0 |
40 |
| V16010 |
4 |
10 |
105/30 |
10 [1-10 (105/30)] |
0.728 |
18,5 |
29 |
53 |
40 |
5.8 |
47 |
| V16008 |
4 |
8 |
7x19/29 |
8 [4 No. 14 (41/30)] |
0.920 |
23,4 |
30 |
54 |
55 |
7.4 |
59 |
| V16006 |
4 |
6 |
7x19/27 |
6 [4 No. 12 (65/30)] |
1.017 |
25,8 |
33 |
60 |
75 |
8.1 |
65 |
| V16004 |
4 |
4 |
7x19/25 |
4 [4 No. 10 (105/30)] |
1.157 |
29,4 |
37 |
67 |
95 |
9.3 |
74 |
| V16002 |
4 |
2 |
7x19/23 |
2 [4 No. 8 (133/30)] |
1.317 |
33,5 |
40 |
72 |
130 |
10.5 |
84 |
SERIES
V - VARIABLE FREQUENCY DRIVE CABLE WITH BRAKE PAIR
Alpha Part No. |
No.
of
Cond. |
No.
of
Pairs |
Conductor
|
Brake Pair
|
Drain Wire Equiv. AWG Size [Physical Drains - AWG - (Strand)]
|
|
| Conductor To Conductor, pF/Ft |
Conductor To Shield, pF/Ft |
Continuous Current Per Conductor, Max. @30C (NEC) |
|
|
| V16116 |
4 |
1 |
16 |
26/30 |
14 |
7/22 |
16 [1-16 (26/30)] |
0.710 |
18,0 |
21 |
38 |
8 |
5.7 |
45 |
| V16114 |
4 |
1 |
14 |
41/30 |
14 |
7/22 |
14 [1-14 (41/30)] |
0.740 |
18,8 |
23 |
42 |
20 |
5.9 |
47 |
| V16112 |
4 |
1 |
12 |
65/30 |
14 |
7/22 |
12 [1-12 (65/30)] |
0.780 |
19,8 |
26 |
47 |
30 |
6.2 |
50 |
| V16110 |
4 |
1 |
10 |
105/30 |
14 |
7/22 |
10 [1-10 (105/30)] |
0.880 |
22,4 |
29 |
53 |
40 |
7.0 |
56 |
| V16108 |
4 |
1 |
8 |
7x19/29 |
14 |
7/22 |
8 [4 No. 14 (41/30)] |
1.030 |
26,2 |
30 |
54 |
55 |
8.2 |
66 |
|
|